Write your numbers once. Every section below recalculates as you type, in the order of the four steps of the book.
The example cabin is Chapter 3 of the book. Use it to check that this page gives the numbers you see there.
1 · Load
Write a month only where its load differs. An empty month uses the daily energy above (Wh/day).
2 · Peak sun hours
Twelve values for your site (h/day), written from the source you chose in Chapter 6. This page does not look them up.
3 · Design month
Ratio = load of the month ÷ peak sun hours of the month. The highest ratio marks the design month.
4 · Battery
| Output capacity, E_dm × days | — |
| Output capacity in amp-hours | — |
| Rated capacity, output ÷ (depth of discharge × derating) | — |
| Rated capacity in amp-hours | — |
5 · Panels
| Panel power from the sum, E_dm ÷ (efficiency × (1 − losses)) ÷ PSH_dm | — |
| Array power, whole panels rounded up | — |
| Charge controller, bare sum (array ÷ voltage, rounded up) | — |
| Inverter, minimum continuous power | — |
6 · Twelve-month check
produced = array × sun of the month × (1 − losses) × battery efficiency. Gap = load of the month − produced, never below 0. Figures are rounded to whole watt-hours, as in Worksheet 13.1.
produced load of the month red figure gap in Wh/day
7 · Levers
Change one number or several. The right column shows the numbers that follow, next to the numbers you wrote. An empty field keeps your number. The load change is added to every month.
The page shows arithmetic. Which lever to move, and why, is in Chapter 13.
8 · Existing system
Write the battery and the panels you already have. The load, the sun, the efficiency and the losses are the ones above.
9 · Summary to print
One page for a professional. Print it, or choose “Save as PDF” in the print window of your browser.